hi all
today my D24 woud not start in park or neutral , a d24 owner helped me to diagnose ,its most likely the inhibitor switch ,
can anyone help me with this problem ?car does start intermittently but ive got to get this fixed
regards jim
Reply With Quote
  #2  
Old 07-31-2022, 12:19 PM
ngoma ngoma is offline
Supporting Member
 
Join Date: Nov 2009
Posts: 1,351
Default

My starter sometimes doesn't like to crank, seems like it can get in a state where the solenoid is lazy to engage, or maybe the rotor lands in a "dead" position. The workaround that works every time is to whack it with a section of small steel pipe. Have you tried that?
__________________
1985 744 gle d24t
1985 745 gle d24t
Reply With Quote
  #3  
Old 08-05-2022, 05:18 PM
v8volvo v8volvo is offline
Supporting Member
 
Join Date: Jun 2009
Location: Montana, USA
Vehicle: '86 745, '83 764
Posts: 1,618
Default

Does it start better if you jiggle the transmission gear selector around? If the park-neutral safety switch is going out that can sometimes be a sign. Or this can also be the sign of a dying starter that is ready for rebuild or replacement.

I've had a few different Volvos over the years (both gas and diesel) where I ended up having to add a standard style relay into the starter circuit. I think over a long enough time with enough wear and corrosion in all the contact points in the circuit (PNP switch, igntion switch, several connectors, many feet of wire) resulting in some voltage drop to the starter, when combined with an aging starter solenoid that may be getting a little weak, you can end up with a situation where the starter does not engage when you turn the key. Adding a relay in the circuit that is triggered by the starter signal wire to supply full clean battery voltage to the solenoid has been a reliable workaround for me. Although not the most elegant.

Smacking it with a piece of pipe can always work too, as noted, but if your issue gets severe enough that you are having to hit it with the pipe several times a day, then addressing it with a starter refresh and/or circuit diagnostics may have more appeal for you.
__________________
86 745 D24T/ZF 345k lifted 2.5"
83 764 D24T/M46 155k
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -8. The time now is 12:55 AM.


Powered by vBulletin® Version 3.8.10
Copyright ©2000 - 2024, vBulletin Solutions, Inc.