D24T.com  

Go Back   D24T.com > Technical Discussion Area > Performance and aftermarket
Register FAQ Community Calendar Today's Posts Search

Reply
 
Thread Tools Display Modes
  #1  
Old 12-22-2013, 08:43 AM
swital swital is offline
Member
 
Join Date: Nov 2013
Location: Płock
Posts: 31
Default

Okej, thanks guys We will see the power on the 1.2bar
__________________
now: 480S, 480 Collection 158, 744 USA FK+ M90, 744 USA, 245 USA D24T+ +IC, 850 T-5R, 945 FK, 440, 460

ex: 745 USA FT, 480S, 3x480ES, 2xV70I, 945 D24TIC, 440
Reply With Quote
  #2  
Old 04-05-2014, 11:07 AM
swital swital is offline
Member
 
Join Date: Nov 2013
Location: Płock
Posts: 31
Default

MBC have plugged as shown in the scheme below, to the hose 1 from post above. However, the turbo did not respond to the shooting mbc, blows to 0.7 bar, and so holds. The valve itself is OK, this type only regulates the flow of air through each other and that it works. Air flow through the tee toward the wastegate. Blowing from the wastegate and mbc in cold side turbo lack of routes, which probably good, just as I blow from the cold air that goes to the wastegate and mbc. All kind of okay, and the lack of regulation.
__________________
now: 480S, 480 Collection 158, 744 USA FK+ M90, 744 USA, 245 USA D24T+ +IC, 850 T-5R, 945 FK, 440, 460

ex: 745 USA FT, 480S, 3x480ES, 2xV70I, 945 D24TIC, 440
Reply With Quote
  #3  
Old 04-05-2014, 03:58 PM
745 TurboGreasel 745 TurboGreasel is offline
Senior Member
 
Join Date: Sep 2012
Location: Freedom CA
Vehicle: 85 745, 84Suburban 96Ram
Posts: 509
Default

Put it where the T is, and ignore the 3rd line that you will no longer have.
Dead end of 3rd line in pic goes to wastegate.
You might need about an 0.020" bleed hole downstream of the controller.

Last edited by 745 TurboGreasel; 04-05-2014 at 04:00 PM.
Reply With Quote
  #4  
Old 04-07-2014, 11:31 AM
swital swital is offline
Member
 
Join Date: Nov 2013
Location: Płock
Posts: 31
Default

I have mbc bleed type and I think this is a problem. MBC have small vent whole and pressure escapes not enough. I need to buy mbc type pressure
__________________
now: 480S, 480 Collection 158, 744 USA FK+ M90, 744 USA, 245 USA D24T+ +IC, 850 T-5R, 945 FK, 440, 460

ex: 745 USA FT, 480S, 3x480ES, 2xV70I, 945 D24TIC, 440
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -8. The time now is 12:03 AM.


Powered by vBulletin® Version 3.8.10