1. When did this problem start happening? After a fuel filter replacement? Some time after running biodiesel?

2. What is the condition of the fuel hose between fuel filter <==> IP?

3. Have you checked that the banjo fittings on the filter head are tight? Hose clamps? Air bleed screw?

4. Does the fuel filter have a drain valve at the bottom?

As you can see, I'm concentrating on the area around the fuel filter/filter head. Can you add a section of clear fuel hose immediately downstream of the filter? That way we could perceive better the source of air ingress.

Low pressure (<5 PSI) electric fuel pump should be OK.

No clue about any squeak after shutdown. Have you tried using a mechanics stethescope?
__________________
1985 744 gle d24t
1985 745 gle d24t
Reply With Quote